Command Entry: UNDO
← Prev | ↑ Chapter | Next → | Index | Symbols
Command Entry: UNDO
Name
UNDO
Aliases
None.
Synopsis
Reverses the effect of one or more commands.
Options
Auto / Control / BEgin / End / Mark / Back / Number
Argument Sequence
number of operations to undo, or an option (Mark/Back/BEgin/End/Control/Auto)
Description
Reverses one or more previous operations, reporting the commands undone, and provides Mark/Back and Begin/End grouping and Control options that govern how undo information is recorded. Certain commands cannot be undone.
Category
edit
Availability
- AutoCAD, all versions: documented.
- BricsCAD, all versions: documented.
- clautolisp: Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log.
Compatibility
AutoCAD all; BricsCAD all.
clautolisp
Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log. Support tier: deferred – in scope eventually, not scheduled now.