Command Entry: CLEANUNUSEDVARIABLES

← Prev | ↑ Chapter | Next → | Index | Symbols

Command Entry: CLEANUNUSEDVARIABLES

Name

CLEANUNUSEDVARIABLES

Aliases

None.

Synopsis

Purges parametric variables not used by constraint expressions and not linked to dimensions.

Options

None.

Argument Sequence

No arguments or inputs are specified; the command executes without requiring user input at the command line.

Description

Automatically removes unused parametric variables from drawings. It deletes variables that are neither referenced by constraint expressions nor associated with dimensions when executed.

Category

parametric

Availability

  • AutoCAD: not documented.
  • BricsCAD V25: documented.
  • clautolisp: Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log.

Compatibility

BricsCAD V25 only. AutoCAD: not present.

clautolisp

Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log. Support tier: package-specific – one vendor's surface; specified and classified, not scheduled for implementation.