Command Entry: CLEANUNUSEDVARIABLES
← Prev | ↑ Chapter | Next → | Index | Symbols
Command Entry: CLEANUNUSEDVARIABLES
Name
CLEANUNUSEDVARIABLES
Aliases
None.
Synopsis
Purges parametric variables not used by constraint expressions and not linked to dimensions.
Options
None.
Argument Sequence
No arguments or inputs are specified; the command executes without requiring user input at the command line.
Description
Automatically removes unused parametric variables from drawings. It deletes variables that are neither referenced by constraint expressions nor associated with dimensions when executed.
Category
parametric
Availability
- AutoCAD: not documented.
- BricsCAD V25: documented.
- clautolisp: Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log.
Compatibility
BricsCAD V25 only. AutoCAD: not present.
clautolisp
Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log. Support tier: package-specific – one vendor's surface; specified and classified, not scheduled for implementation.