Command Entry: CHECKSTANDARDS
← Prev | ↑ Chapter | Next → | Index | Symbols
Command Entry: CHECKSTANDARDS
Name
CHECKSTANDARDS
Aliases
None.
Synopsis
Checks the current drawing for inconsistencies that violate the standards.
Options
None.
Argument Sequence
Takes no command-line arguments; it opens the Check Standards dialog box where violations are reviewed, fixed with a replacement, or marked as ignored.
Description
Audits the current drawing against defined CAD standards (a .dws standards file specifying layers, dimension styles, linetypes, and text styles) and displays the Check Standards dialog box to identify and manage violations.
Category
inquiry
Availability
- AutoCAD, all versions: documented.
- BricsCAD, all versions: documented.
- clautolisp: Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log.
Compatibility
AutoCAD all; BricsCAD all.
clautolisp