Command Entry: BMHARDWARE

← Prev | ↑ Chapter | Next → | Index | Symbols

Command Entry: BMHARDWARE

Name

BMHARDWARE

Aliases

None.

Synopsis

Opens the Library panel in BricsCAD Mechanical.

Options

None.

Argument Sequence

No command-line arguments; opens the Library panel as a dockable panel in the current workspace.

Description

Opens the Library panel to display it in the current workspace. The panel retains its previous size and location and functions as a standard dockable panel that can be floated, docked, or stacked.

Category

block

Availability

  • AutoCAD: not documented.
  • BricsCAD V25: documented.
  • clautolisp: Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log.

Compatibility

BricsCAD V25 only. AutoCAD: not present.

clautolisp

Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log. Support tier: package-specific – one vendor's surface; specified and classified, not scheduled for implementation.