Command Entry: ADCNAVIGATE
← Prev | ↑ Chapter | Next → | Index | Symbols
Command Entry: ADCNAVIGATE
Name
ADCNAVIGATE
Aliases
None.
Synopsis
Loads a specified drawing file, folder, or network path in the DesignCenter Folders tab.
Options
None.
Argument Sequence
A pathname string: either a folder path or a folder path plus a filename (local drive or mapped drive); UNC network paths are not supported.
Description
Navigates to and opens a specified drawing file or folder within the DesignCenter Folders tab. It works with local paths and mapped drives but does not support UNC network paths, prompting for the pathname at the command line.
Category
block
Availability
- AutoCAD, all versions: documented.
- BricsCAD: not documented.
- clautolisp: Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log.
Compatibility
AutoCAD all only. BricsCAD: not present.
clautolisp
Not yet implemented: (command …) stops at it, with a "; cador:" notice on the console and no AutoLISP error; the call is recorded on the command log. Support tier: package-specific – one vendor's surface; specified and classified, not scheduled for implementation.